Classification
Articles
止凝血功能指標(biāo)在乙肝、肝硬化及肝衰竭患者中的變化規(guī)律
ELISA實(shí)驗(yàn)中的封閉液等常用試劑的配制
產(chǎn)品展示/ Product display
HSD17b3抗原;17-β-羥基類固醇脫氫酶3(HSD17b3)重組蛋白多種屬 HSD17B3參與雄烯二酮還原為睪酮。它主要在睪丸中表達(dá)。HSD17B3缺乏是男性假兩性畸形伴男性乳房發(fā)育癥(MPH)的原因。
聯(lián)系電話:15221858802
品牌 | 信裕生物 | CAS | 詳見說明書 |
---|---|---|---|
分子式 | 詳見說明書 | 純度 | > 90% |
分子量 | 38.2kDa | 貨號(hào) | XY90011RPHu |
規(guī)格 | 50µg/100µg | 供貨周期 | 一周 |
主要用途 | SDS-PAGE; WB | 應(yīng)用領(lǐng)域 | 生物產(chǎn)業(yè) |
Recombinant 17-Beta-Hydroxysteroid Dehydrogenase Type 3 (HSD17b3)
17-β-羥基類固醇脫氫酶3(HSD17b3)重組蛋白
[ PROPERTIES ]
Source: Prokaryotic expression
Host: E.coli
Residues: Met1~Arg310
Tags: N-terminal His Tag
Subcellular Location: Endoplasmic reticulum lumen
Purity: > 90%
Traits: Freeze-dried powder
Buffer formulation: PBS, pH7.6, containing 0.01% SKL, 5% Trehalose.
Original Concentration: 120µg/mL
Applications: Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point: 8.9
Predicted Molecular Mass: 38.2kDa
Accurate Molecular Mass: 33kDa as determined by SDS-PAGE reducing conditions.
Phenomenon explanation:
The possible reasons that the actual band size differs from the predicted are as follows:
1.Splice variants: Alternative splicing may create different sized proteins from the same gene.
2. Relative charge: The composition of amino acids may affects the charge of the protein.
3. Post-translational modification: Phosphorylation, glycosylation, methylation etc.
4. Post-translation cleavage: Many proteins are synthesized as pro-proteins, and then cleavedto give the active form.
5. Polymerization of the target protein: Dimerization, multimerization etc.
[ USAGE ]
Reconstitute in 10mM PBS (pH7.4) to a concentration of 0.1-1.0 mg/mL. Do not vortex.
[ STORAGE AND STABILITY ]
Storage: Avoid repeated freeze/thaw cycles.
Store at 2-8oC for one month.
Aliquot and store at -80oC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
[SEQUENCE ]
[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit was used in clinical diagnostic or any other procedures.
特別提示:本公司的所有產(chǎn)品僅可用于科研實(shí)驗(yàn),嚴(yán)禁用于臨床醫(yī)療及其他非科研用途!以實(shí)際收貨產(chǎn)品說明書為準(zhǔn),網(wǎng)站說明書僅供參考!
電話